Troubleshooting for IT

VDZ does not start

Message or symptomCauseFix
a compatible graphics adapter is requiredNo graphics adapter that VDZ can use. Common on virtual machines and remote desktop hosts.Update the graphics driver, or turn on graphics acceleration for the virtual machine. See System requirements.
A Windows message that names VCRUNTIME140.dll or MSVCP140.dllThe Microsoft Visual C++ Redistributable is missing.Install the current x64 Visual C++ Redistributable from Microsoft.
The first time the VDZ demo starts it needs the internetThe demo could not read the date.Allow the hosts in Network access and privacy, then start VDZ again.
This VDZ demo’s trial record is damagedThe demo could not read or save its trial record on this computer, for example after a profile was copied from another computer. A damaged record next to a good one does not cause this: VDZ writes it again.Contact HyEnergy Solutions and give the code at the end of the message.
The sign-in screen says VDZ couldn’t reach the licensing portalThe full version cannot reach the licensing hosts.Allow the hosts in Network access and privacy. A computer with no internet cannot use the full version. See Computers without internet access.
VDZ asks a user to sign in again on a computer that was signed inThe computer was removed from the licence, VDZ could not check the licence for 30 days, the clock was set back, or the computer’s fingerprint changed (a reinstalled operating system or a cloned disk image).Correct the cause, then the user signs in again. See Licence checks.
VDZ could not start, with a folder nameAn error at startup.Send the newest report in that folder to HyEnergy Solutions.

“No library found”

VDZ found no .vdl file in the libraries folder of its root folder.

  1. On the affected computer, open Preferences → Libraries and read VDZ root folder.
  2. Check that the folder has a libraries folder with .vdl files in it, and that the user can read them.
  3. If the folder is on a share, check that the share is connected.
  4. Click Reload.

See Files and folders for how VDZ chooses the folder.

A project will not open: “open in another VDZ”

See Project files on shared drives.

The user needs write access to the conversions folder of the VDZ root folder.

Finding error reports

Each crash or serious error makes a text file in the ErrorReports folder of the VDZ root folder. The files are named VDZ crash or VDZ error, with the date and time. Send the report that matches the time of the problem to HyEnergy Solutions.

An error report starts with the message the user saw. Its Detail line is the technical cause, which the status bar does not show.

VDZ writes no other log.

Resetting a user’s preferences

Close VDZ and delete config.toml from the user’s preferences folder. See Files and folders. VDZ starts with its defaults and shows Quick Start again.